Small Size Flow Sensor

YF-S401-03507 Hall Effect Water Flow Sensor

YF-S401-03507 Hall effect water flow sensor, POM valve body, 7mm port, flow range 0.5~5L/min, withstand pressure ≤0.8MPa, operating voltage DC3.5~24V, accuracy ±2%, suitable for clean liquid flow measurement.

YF-S401-03507 Hall Effect Water Flow Sensor Specifications

YF-S401-03507 Hall Effect Water Flow Sensor

Product Overview

YF-S401-03507 7mm Port

High-precision Hall effect flow sensor with a stable impeller measurement structure, suitable for flow measurement of water and low-concentration liquids. Features a high-strength POM valve body with excellent consistency and long-term stability. Supports 7mm port, flow range 0.5~5L/min, clear pulse output signal, ideal for PLCs, controllers, and metering systems.

Product Features

  • Hall effect impeller design, pulse output proportional to flow rate, accuracy up to ±2%

  • High-strength POM valve body, stable measurement of various clean liquid media

  • Industrial-grade safety design, supports DC3.5-24V wide voltage input, high insulation resistance, excellent anti-interference performance

  • Optimized inner/outer diameter and thread length design, secure installation, reliable sealing

Product Images

YF-S401-03507 Hall Effect Water Flow Sensor
YF-S401-03507 Drawing
YF-S401-03507 Detailed Picture
YF-S401-03507 Dimensions

Technical Specifications

ModelYF-S401-03507
Port Size7mm
Flow Range0.5~5L/min
Applicable MediaWater, low-concentration liquids
Withstand Pressure≤0.8MPa
Operating VoltageDC3.5~24V
Valve Body MaterialPOM
Insulation Resistance>100MΩ
Accuracy±2%
Flow Pulse CharacteristicF=(43×Q)±2%, F is frequency, Q is L/min, i.e. 2580 pulses per liter
Output Pulse High Level>DC4.7V (input voltage DC5V)
Output Pulse Low Level<DC0.5V (input voltage DC5V)
Output Pulse Duty Cycle50%±10%
Thread Length14mm
Inner/Outer DiameterInlet inner diameter 3.5mm, outer diameter 7.2mm

Notes on Specifications

1. The values listed are for reference only.

2. The number of pulses per liter may vary depending on the medium and installation conditions.

3. It is recommended to calibrate the number of pulses per liter based on the complete installation.

Usage Tips

  • Ensure there is no rapid pulsation in the medium

  • Ensure there is no reverse pressure surge

  • Ensure there is no air in the system

  • Minimize pressure loss as much as possible

  • Pay attention to the installation position of the flow meter

  • The minimum/maximum flow rate should be within the linear range of the selected flow meter

  • Clean the system regularly

  • Avoid current peaks

  • Incorrect wiring of power positive, signal line, and ground will damage the flow meter

  • Do not apply mechanical load to electrical contacts

  • Keep electrical contacts away from moisture

  • Avoid stray interference through cables (EMI) (do not route cables parallel to high-current loads)

Precautions

  • To prevent particles and debris from entering the product, a filter screen must be installed at the water inlet.

  • The product must be installed indoors or inside equipment. Do not expose it to outdoor, humid, or high-temperature environments for extended periods. Avoid installation in vibrating or shaking environments, as this may affect measurement accuracy.

  • When magnetic materials or materials that generate magnetic force approach the product, its characteristics may change.

  • Do not disassemble the product. Any product that has been disassembled is not covered by warranty.

  • If you have not used this type of sensor before, direct substitution may cause compatibility issues. Please take note.

  • Do not blow high-speed air into this product, as it will damage internal components, causing inaccurate flow characteristics or no output.

  • We reserve the right to update and improve products for technological advancement.

Applications

Gas water heaters, electric water heaters, instant water heaters, wall-hung boilers, solar water heaters, heat pump water heating systems, washing machines, dishwashers, smart bathroom equipment, water purifiers, water dispensers, boiling water dispensers, vending machines, water control systems, IC card water meters, smart water meters, hot water meters, campus card water systems, bathroom water control systems, industrial cooling systems, circulating water systems, boiler systems, central air conditioning, refrigeration equipment, water treatment equipment, chemical dosing equipment, agricultural irrigation systems, chemical metering equipment, pharmaceutical equipment, food and beverage processing equipment, medical equipment, car wash equipment, swimming pool circulation systems, smart mechanical equipment, instruments and meters

Company Images

wire-connection
isentrol-factory

SEO Information

KeywordsYF-S401-03507 Hall effect water flow sensor,7mm port water flow meter,POM body flow sensor,miniature water flow sensor
Page DescriptionYF-S401-03507 Hall effect water flow sensor, POM valve body, 7mm port, flow range 0.5~5L/min, withstand pressure ≤0.8MPa, operating voltage DC3.5~24V, accuracy ±2%, suitable for clean liquid flow measurement.
TagsYF-S401-03507|Hall effect flow sensor|water flow meter|7mm port|POM body
Static Page Nameyf_s401_03507_hall_effect_water_flow_sensor

热门推荐

Home
Product
News
Contact